1932 Arthur Avenue
Tremont, Bronx 10457
Block 2947, Lot 18BIN 2009911
5active devices
24active violations
0issued 2 Oct 2026
2026oldest Cat 1 test on file
Get an email when this building changes
Devices
| Device | Status | Last Cat 1 test | Last Cat 5 test | Active violations | Source |
|---|---|---|---|---|---|
| 2P2333Elevator | Active | 29 Apr 2026 | 28 Mar 2024 | 4 active | |
| 2P2334Elevator | Active | 29 Apr 2026 | 28 Mar 2024 | 4 active | |
| 2P2341Elevator | Active | 29 Apr 2026 | 29 Mar 2024 | 4 active | |
| 2P2342Elevator | Active | 29 Apr 2026 | 29 Mar 2024 | 4 active | |
| 2P2343Elevator | Active | 22 May 2026 | 29 Mar 2024 | 4 active |
Boilers
| Boiler | Last inspection filed | Report | Defects | Filing status | Source |
|---|---|---|---|---|---|
| 20000067835N0001Low Pressure | 28 Sep 2026 | Initial | No | Pre-filing | |
| 20000067835N0002Low Pressure | 28 Sep 2026 | Initial | No | Pre-filing | |
| 20000067835N0003Low Pressure | 28 Sep 2026 | Initial | No | Pre-filing |
Violations since 2019
ViolationIssued 2 Oct 2026Last Cat 1 test on file
Violations in the last two years
| Issued | Violation | Device | DOB says | Status |
|---|---|---|---|---|
10 Oct 2025 | VIO-FTC-VT-PER-202412-0007281 | 2P2341 | Periodic defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-PER-202412-0007280 | 2P2334 | Periodic defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-PER-202412-0005101 | 2P2333 | Periodic defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-PER-202412-0004832 | 2P2343 | Periodic defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-PER-202412-0000404 | 2P2342 | Periodic defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-CAT1-202412-0006157 | 2P2342 | Cat 1 defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-CAT1-202412-0006156 | 2P2341 | Cat 1 defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-CAT1-202412-0006155 | 2P2334 | Cat 1 defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-CAT1-202412-0000440 | 2P2343 | Cat 1 defects: correction not filed | Active |
10 Oct 2025 | VIO-FTC-VT-CAT1-202412-0000439 | 2P2333 | Cat 1 defects: correction not filed | Active |
40 earlier violations, back to 2019, are in the Compliance Report.
These violations mean DOB had no report on file for that cycle. It is not a finding that a device is unsafe, and the owner may have filed since. Current status on DOB BIS
Guides: what a failure-to-file notice means · how penalties work · boiler annual filing
Public NYC records as of 27 Oct 2026. Not an inspection, a compliance certificate or legal advice. Not affiliated with NYC DOB.