Inspection Lookup

Data updated 27 Oct 2026

701 7th Avenue

Midtown-Times Square, Manhattan 10036

Block 1000, Lot 1Built 1909Height 124 ftBIN 1083718

18active devices
33active violations
0issued 2 Oct 2026
2025oldest Cat 1 test on file

Get an email when this building changes

Devices

DeviceStatusLast Cat 1 testLast Cat 5 testActive violationsSource
1W7158Accessibility Lift
Active
8 Jul 2026
—
6 active
1P49332Elevator
Active
10 Jul 2026
4 Dec 2024
2 active
1P49343Elevator
Active
10 Jul 2026
12 Dec 2024
2 active
1P49348Elevator
Active
10 Jul 2026
6 Dec 2024
2 active
1P49349Elevator
Active
10 Jul 2026
3 Dec 2024
2 active
1P49350Elevator
Active
10 Jul 2026
19 Sep 2022
2 active
1P49351Elevator
Active
10 Jul 2026
5 Dec 2024
2 active
1P49753Elevator
Active
3 Aug 2026
19 Sep 2022
2 active

15 more devices are in the full report.

Boilers

BoilerLast inspection filedReportDefectsFiling statusSource
10000203909N0001Low Pressure
10 Jul 2026
Initial
No
Accepted
10000203910N0002Low Pressure
10 Jul 2026
Initial
No
Accepted
10000205132N0003Low Pressure
10 Jul 2026
Initial
No
Accepted
10000205133N0004Low Pressure
10 Jul 2026
Initial
No
Accepted

Violations since 2023

1W71581P497701P497721P49753Other2023202420252026

ViolationIssued 2 Oct 2026Last Cat 1 test on file

Violations in the last two years

IssuedViolationDeviceDOB saysStatus
10 Oct 2025
VIO-FTC-VT-PER-202412-0008450
1P49351
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-PER-202412-0006720
1P49355
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-PER-202412-0004557
1P49343
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-PER-202412-0004454
1P49348
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-PER-202412-0002907
1P49353
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-PER-202412-0002185
1P49332
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-PER-202412-0001901
1P49354
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-PER-202412-0000761
1P49349
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-PER-202412-0000577
1P49352
Periodic defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-CAT1-202412-0006066
1P49771
Cat 1 defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-CAT1-202412-0004220
1P49770
Cat 1 defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-CAT1-202412-0004125
1P49772
Cat 1 defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-CAT1-202412-0003307
1W7158
Cat 1 defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-CAT1-202412-0002159
1V23909
Cat 1 defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-CAT1-202412-0000478
1F10363
Cat 1 defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-CAT1-202412-0000276
1P49753
Cat 1 defects: correction not filed
Active
10 Oct 2025
VIO-FTC-VT-CAT1-202412-0000149
1P49350
Cat 1 defects: correction not filed
Active

30 earlier violations, back to 2023, are in the Compliance Report.

These violations mean DOB had no report on file for that cycle. It is not a finding that a device is unsafe, and the owner may have filed since. Current status on DOB BIS

Guides: what a failure-to-file notice means · how penalties work · boiler annual filing